Quadro shunt modules SCQ25, SCQ25T and SCQ50

WHAT'S IN THE BOX?

Quadro shunt SCQ25, SCQ50 or SCQ25T

5 m data cable

Screws

Warranty

A true innovation on the market! Quadro low-amp shunt modules are here for appliance monitoring.

With them you can monitor the current flow of the 4 individual appliances. The SCQ25 allows a maximum continuous current of 25 amps per channel and the SCQ50 allows a maximum continuous current of 50 amps per channel.

If you need more than 25 amps per channel, you can wire the appliance in parallel across two channels and configure this setting in PICO to monitor these two channels as a single device, thus doubling the continuous current limit (2×25 = 50A).

What about the SCQ25T module? This is an innovative combination of SCQ25 and ST107 tank level and voltage module. It combines the functionalities of both modules.

Connection possibilities:

– 4 appliances (consumers and/or generators)
– 1 alarm signal relay

The alarm signal relay’s voltage limit is 60V and the current limit is 1A.

HOW TO CONNECT

monitoring current for each appliance

WIRING OPTIONS

wiring shunts

You can wire the shunts to either the LOW (-) or HIGH side (+), unless the system’s voltage exceeds 35V. In this case, wiring the shunt to the LOW(-) side is mandatory.

You can also mix the shunt wirings, by connecting some to the positive and some to the negative side, or even to the same module.

Convenient for wiring on retrofitting for existing boats and campervans.

Multiple shunts can be daisy-chained together or linked to our other expansion modules.

Play Video

Techtalk

Operating
Voltage range6 - 35 VDC
Temperature range​From -20°C up to 70°C (-4°F up to 158°F)
Power consumption at 12 V
Operating​2.5 mA
Current Measuring (per channel)
Range0.01 – 25 A
Accuracy ± 1%
Resolution 0.01 A
Sampling rate 100 ms
Maximal current
Voltage drop at 300 A 30 mV
Continuous 25 A
Peak current (<1min) 35 A
Dimensions 183 x 91 x 34 mm
Current channels4
ConnectivitySiCOM
Alarm contact1
Operating
Voltage range6 - 35 VDC
Temperature range​From -20°C up to 70°C (-4°F up to 158°F)
Power consumption at 12 V
Operating​2.5 mA
Current Measuring (per channel)
Range0.01 – 50 A
Accuracy ± 1%
Resolution 0.01 A
Sampling rate 100 ms
Maximal current
Voltage drop at 300 A 35 mV
Continuous 25 A
Peak current (<1min) 35 A
Dimensions 183 x 91 x 34 mm
Current channels4
ConnectivitySiCOM
Alarm contact1
Operating
Voltage range6 - 35 VDC
Temperature range​From -20°C up to 70°C (-4°F up to 158°F)
Power consumption at 12 V
Operating​2.5 mA
Current Measuring (per channel)
Range 0.01 - 25 A
Accuracy ± 1%
Resolution 0.01 A
Sampling rate 100 ms
Maximal current
Continuous 25 A
Peak current (<1min) 35 A
Voltage inputs (U1, U2, U3)3
Range 0 - 75 VDC
Resolution 1 mV
Accuracy ± 0.3 %
Sampling rate 100 ms
Resistance inputs (R1, R2, R3, R4) 4
Range 0 Ohm–65 kOhm
Accuracy ±3 %
Dimensions
183 x 91 x 34 mm
7.20 x 3.58 x 1.33 in
ConnectivitySiCOM
Alarm contact1